Frequently Asked Question
Remove or replace a QNAP SSD cache without pulling drives that still hold pending writes
Remove an SSD cache through the supported storage controls before physically removing its SSDs. A write cache can contain data that has not yet reached the main storage pool.
Applies to: QTS 5.2 SSD-cache management. QuTS hero and other releases have different cache types and controls; use the exact model and operating-system procedure.
1. Identify the Cache Before Touching Hardware
In Storage & Snapshots, identify the cache, its mode, participating SSDs and the volumes/LUNs using it. Confirm that the SSD is not a storage-pool member or Qtier tier. Those are different roles, even if the same physical SSD model can be used for them.
Record the current storage status and check the independent backup. If required files are accessible, verify a representative recovery copy before a planned hardware change.
2. Stop if the Storage Is Already Abnormal
A Cache Missing message is not permission to remove the cache configuration. Missing write-cache data can make dependent volumes unavailable. Likewise, a read-only pool may prevent pending cache data from being written back.
If the pool is read-only, the cache is missing or SSDs have failed, preserve the original drives and positions. Obtain a recovery plan rather than forcing cache removal. Do not initialise the pool or accept a data-loss warning merely to make storage appear online.
3. Remove a Healthy Cache Through QTS
- Schedule the change and reduce application writes to the affected storage. Ensure no conflicting storage operation is in progress.
- Open Storage & Snapshots > Storage > Cache Acceleration for the applicable QTS 5.2 interface.
- Select the intended cache and review Manage > Remove. Confirm that the selected object is the cache, not the data pool or volume.
- Read the warning and allow QTS to flush pending data and finish removing the cache. Do not interrupt the process or pull an SSD while it is still active.
- Confirm that cache removal completed and the affected volumes remain accessible and healthy.
4. Follow the Hardware Service Procedure
Only after safe removal should the SSDs be physically serviced. Check the NAS manual for the bay or M.2 slot involved; a hot-swappable front bay does not make an internal M.2 module hot-swappable. Power down where the model instructions require it.
For a replacement cache, check SSD compatibility, endurance, supported layout and the data-erasure warning for selected SSDs. Reusing an SSD from another role requires an explicit data-preservation decision.
5. Verify Service
Check important files, application reads/writes, storage health and the next backup. Record the final cache/storage state. Do not promise faster operation simply because a cache was recreated; suitability depends on the workload.
For private support, include the model, QTS build, cache mode and exact status messages. Never discard the original cache SSDs while recovery remains unresolved.
Updated 261117